top of page
  • Cradle for battery charging, connection to a PC and automatic data exchange saving time and eliminating errors.
  • Assured hygiene with removable flowhead and Vitalograph Bacterial Viral Filters (BVF)
  • Hours of battery life for a full day of off-site testing
  • Over 50 test parameters
  • Pre-post bronchodilator comparison
  • Single and multi-breath
  • F/V or V/T curves viewable in real time
  • Choice of child incentives with sound effects
  • Remote flowhead option enables the subject to view incentives while performing the test
  • Icon driven menus
  • Print via your PC or via Spirotrac Software or print direct to a USB A4/Letter size printer using optional printer cradle
  • Range of accessories and robust carrying case
  • In2itive with Spirotrac® Software allows for automatic data exchange, via HL7 and GDT transfer protocols, with EMR systems and the ability to add other diagnostic tests and physiological measurements (including resting 12-lead ECG, SpO2, NIBP and Audiometry).

     

    Includes:

  • EMIS*
  • Vision*
  • Cohort
  • Medgate
  • SystmOne*
  • Clinic-All
  • eOPAS

 

Vitalograph In2itive with USB PC Cradle and Spirotrac Software

SKU: 79001
$3,743.75Precio
  • Product Name: In2itive Handheld Spirometer
    Model No: 2120
    Subjects: Automatic population of database from Spirotrac. Name, ID; Age, Height, Gender; Smoking status, Body Mass Index and more depending on model. Storage of up to 10,000 subjects.
    Environmental Data: Selectable: Temperature (built in sensors), Barometric pressure, altitude, humidity.
    Test types: Single breath tests, flow/volume loops, multi-breath testing, tidal breathing and combined VC/FVC type test methods supported
    Selectable Parameters (depending on model): VC; IVC; IC; VT (TV); TLC; RV; IRV; ERV; FRC; FVC; FIVC; FEV1; FEV3; FEV6; FVC; FEV1/VC; FEV1/FVC; FEV3/VC; FEV3/FVC; FEV1/FEV6; FEF75; FEF50; FEF25; FEF25-75; FEF25-75/FVC; FIV1; PIF, FIV1/ FIVC, FIF25, FIF50, FIF75, FEF50/FIF50, FET, MVVind, FEV1 Ratio; FEV0.5; PEF L/min; PEF L/s; FEF 0.2-1.2; FEF 75-85%; FEF25%; FEF50%; FEF75%; FMFT; FIF25%; FIF50%; FIF75%; PIF; FEV0.75; Lung Age and more.
    Predicted Values Selectable(depending on model): ERS/ECCS; GLI, NHANES, Polgar, Pereira, Berglund,Forsche, Gutierrez,Hedenström, Taiwan;Knudson, Crapo; Hsu; KNLW; Viljanen; SEPAR; Gulsvik; SBPT; Tamura; Ip; Quanjer; Wang; Dockery and more
    Suggested Interpretation: User selectable
    Flow Technology: Fleisch Pneumotachograph (No3 size)
    Resolution: 10 mL volume; 0.01 L/s flow
    Data Storage: Stores up to 10,000 subjects and hundreds of test sessions
    Accuracy when in Operating Range: Volumes: Better than ± 3% (Max 10L / Min 0L)
    Flows: Better than ± 10% (Max 16L/s / Min 0.02L/s)
    Linearity: ± 5% in range 0.1 L/s to 16 L/s
    PowerSAFE™: Input 100 - 240V AC 50-60Hz, output 5V DC
    Battery Pack: Rechargeable Lithium Polymer 3.7v 2000mAH
    Dimensions: Device: 160mm x 100mm x 45mm (with flowhead attached)
    Nett Weight: Device: 230g
    Gross Weight and Size (Packed): Weight: 1.5kg, Packed Size: 213mm x 199mm x 158mm
    Storage Humidity: 10% to 95%
    Storage Temperature: 0°C to 50°C
    Recommended Operating Temperature Range: 17 - 37°C; Design Limits 10-40°C
    Ambient Humidity: 0% to 99%
    Connectivity: USB 2
    Max Test Duration: 20s FVC; 30s VC
    Performance Standards: ISO 26782:2009
    ISO 23747:2007
    ATS/ERS 2005
    Safety Standards: IEC 60601-1:2005
    Medical Safety Standard: Medical Devices Directive 2007/47/EC
    Designed & Manufactured Under: ISO 13485:2003 and 2016
    FDA 21 CFR 820
    CMDR